1514AH-39778
Fisher Pierce
Model 1514AM-45102 Smartnet Directional Network FCI, Flag Display, Hotstick Mounting (attached indicator/sensor)
  Compare
1514AM-45102
Fisher Pierce
Model 1514AM-45102 Smartnet Directional Network FCI, Flag Display, Tie-wrap mounting (attached indicator/sensor)
  Compare
1514AP-8Z3-10HD-B
Fisher Pierce
Model 1514AM-45102 Smartnet Directional Network FCI, Flag Display, Window/flush mounting (remote from sensor)
  Compare
1514BH-2C3-NTB-B
Fisher Pierce
Series 1514 Current Reset FCI with LED display and Inrush Restraint. Hotstick Mounting with attached indicator/sensor. 200A Fixed Trip setting. 4 hr reset time delay after fault occurrence with current reset override upon energization of line.
  Compare
1514DH-2Z3-NTD-B-A
Fisher Pierce
Series 1514 Current Reset FCI with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 200A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 60-sec delay after fault occurrence.
  Compare
1514DH-2Z3-NTD-B-B
Fisher Pierce
Series 1514 Current Reset FCI with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 200A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 60-sec delay after fault occurrence.
  Compare
1514DH-2Z3-NTD-B-C
Fisher Pierce
Series 1514 Current Reset FCI with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 200A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 60-sec delay after fault occurrence.
  Compare
1514DH-6J3-NTD-B-A
Fisher Pierce
Series 1514 Current Reset FCI with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 600A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 4-hr reset time delay after fault occurrence with current reset override upon energization of line.
  Compare
1514DH-6J3-NTD-B-B
Fisher Pierce
Series 1514 Current Reset FCI with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 600A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 4-hr reset time delay after fault occurrence with current reset override upon energization of line.
  Compare
1514DH-6J3-NTD-B-C
Fisher Pierce
Series 1514 Current Reset FCI with Integral Radio/LED display. Hotstick Mounting with attached indicator/sensor. 600A Fixed Trip setting. Inrush Restraint, Manual Trip and Manual Reset Override. 4-hr reset time delay after fault occurrence with current reset override upon energization of line.
  Compare